Fire Retardant and Intumescent Coatings for Timber and Related Products offering Class 0/1 and up to 60 minutes:
Suitable for:
- Interior and Exterior Softwoods, Hardwoods, MDF, Chipboard, Melamine faced sheet, Bamboo
- Fire Retardant products for doors, decking, bar-tops, panelling, cladding and floors
- Painted surfaces, Varnished, Stained and Unpainted surfaces
- Clear finishes, White Finishes or Coloured Finishes
For immediate advice, costings and specifications please contact
Phil, Bill or Richard on 01935 414012
|
|
| |
STANDARDS AND PERFORMANCE
The test method used to assess the effectiveness of flame retardant products is BS476, Part 7 1987 and is used to classify a material in terms of "Spread of Flame".
Class 1 is a low surface spread of flame, the highest achievable with the test method and is a performance normally required for walls and ceilings.
In high risk areas such as escape routes Class 0, limited combustibility, is required. To comply materials must have a Class 1 Surface Spread of Flame and a low fire propagation to BS 476 Part 6 1989.
Intumescent coatings are used to prevent the penetration of fire through a structure for a specific period in accordance with BS 476 Parts 20-23 1987. Such coatings are given classifications with specific periods of time achievements, such as "30 minutes".
All fire retardant systems are also tested to EN13501-1:2002. Intumescent coatings are tested to EN 1364-1:1999
All products have been designed for ease of application, environmental considerations and are tested in independent laboratories to both UK and European (EN) Standards.
|
| |
Fire Retardant Wood Coatings
S92 water borne fire retardant coating systems are available for interior and exterior use. Suitable for both new and previously stained timber and timber related products.
They offer protection to Class 1 and 0 on furniture, floors, decking, panelling, wall cladding, soffits and bargeboards.
Fire Retardant/intumescent wood coatings
S42 fire retardant and intumescent coating systems offer protection to BS 476 Parts 6,7,20,21 and 22. They are particularly suitable for the protection of floors (upgrading joists and boards to 30 minutes), decorative panelling and ceiling board. Used with protective lacquers for applications in especially onerous or abrasive situations.
Door upgrades
A range of product designed to upgrade solid timber, panelled and ledged and braced doors in period properties to 30 minute fire doors. For Professional Users only, not suitable for DIY use. |
| |
Intumescent coatings for plasterboard
S96 textured coatings and S105 smooth coatings are intumescent emulsion systems suitable for plasterboard ceilings and walls. They are tested to to BS 476 21 and 22 to provide fire protection of 61 minutes on load bearing plasterboard and 71 minutes on timber stud partitions.
Intumescent products for lath and plaster
S53 Underfloor Fire Barrier and S84 Intumescent Lining Paper offer 104 minutes protection for lath and plaster ceilings and walls. The systems eliminate the need to remove or "double board" ceilings and allow original decorative plasterwork to be displayed.
|
| |
Intumescent coatings for steel
A complete primer, thin-film intumescent and topcoat system for application to interior and exterior, structural steelwork.
Suitable for application over new, primed. galvanized and previously painted steel offering up to 120 minutes protection, depending on the section and orientation of the steel.
TECHNICAL SUPPORT
Specifications are provided for each individual job with an appropriate Certificate of Supply to satisfy the legislation.
With all intumescent and fire retardant coatings product selection and application rates will vary according to the substrate type, orientation, dimensions and the level of protection required.
Remember please contact Phil, Bill or Richard on 01935 414012 if you have any queries, need further information or a specification.